Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 161 - 172172
PDFCat. No. W238-E1-10 SYSMAC CQM1H/CQM1 Series

...a should be input. X1 = 400, X2 = 1500, Y1 = 1000, Y2 = 3000 If the input from the sensor is 10 mA, a value corresponding to the input will be 2091 (i.e., 20.91 centimeters) in this case. X1 ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/w238-e1-10_cqm1-b7a_g7_lk_ad_da_sen_lse_tc.pdf

PDFi516-e1-05_3g3fv.pdf

... V (A 10-V input limits the torque to 100% of the motor’s rated torque.) • Terminal 14: 4 to 20 mA (A 20-mA input limits the torque to 100% of the motor’s rated torque.) 6-4 Chapter 6 Advance...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i516-e1-05_3g3fv.pdf

PDFn090-e1-01b_k3nx.pdf

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input shortcircuiting. 13 Output Board 2-3 Output ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/n090-e1-01b_k3nx.pdf

PDFn093-e1-01a_k3nr.pdf

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input shortcircuiting. 15 Output Board 2-3 Output ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/n093-e1-01a_k3nr.pdf

PDFw371-e1-03_cpm2b.pdf

... below 0.8 V or 3.2 mA, respectively, when the input range is set to either 1 to 5 V or 4 to 20 mA, a disconnection of the input line is detected and the line disconnection detection function...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w371-e1-03_cpm2b.pdf

PDFCat. No. N090-E1-1B K3NX Process Meter

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input shortcircuiting. 13 Output Board 2-3 Output ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/n090-e1-01b_k3nx.pdf

PDFK3NX Process Meter Operation Manual

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input shortcircuiting. 2-3 Output Board 2-3-1 Term...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/n090-e3-1_k3nx.pdf

PDFCat. No. N093-E1-1A K3NR Frequency/Rate Meter

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input shortcircuiting. 15 Output Board 2-3 Output ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/n093-e1-01a_k3nr.pdf

PDFK3NV Weighing Meter Operation Manual

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input shortcircuiting. 2-3 Output Board 2-3-1 Term...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/n91-e3-1_k3nv.pdf

PDFCat. No. W371-E1-03 SYSMAC CPM2B

... below 0.8 V or 3.2 mA, respectively, when the input range is set to either 1 to 5 V or 4 to 20 mA, a disconnection of the input line is detected and the line disconnection detection function...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/w371-e1-03_cpm2b.pdf

PDFCat. No. W457-E1-08 CRT1 Series

...ue falls below the input range such as for a disconnected line (input current is less than 3.04 mA), a disconnected line detection function activates and data is set to 7FFF Hex. Conversion d...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/w457-e1-08_crt_crs1-rpt01.pdf

検索結果 : オムロン制御機器

...索 商品検索:全1件が検索されました。(1-1件を表示) 商品名/形式/概要 ダウンロード マイカタログ 電磁継電器 MA□A 1995年03月受注終了 ※受注終了品のカタログ、マニュアルのダウンロードにはI-Webメン...

https://www.fa.omron.co.jp/search/product/index?keyword=MA□A

結果 161 - 172172

国/地域選択

Related Contents